[Dec-2021] Dumps Practice Exam Questions Study Guide for the NS0-592 Exam
NS0-592 Dumps with Practice Exam Questions Answers
NEW QUESTION 14
Click the exhibit button.
When you log in to a node, a warning is displayed as shown in the exhibit.
Which statement is correct in this scenario?
- A. One or more RDB db files are damaged due to an internal software error.
- B. The node cannot communicate with the rest of the nodes in the cluster.
- C. The node root volume was moved to a new aggregate.
- D. The partner still hosts the CFO aggregate for the node.
Answer: B
NEW QUESTION 15
A customer called you after a failure in their Microsoft Hyper-V environment on the "SVM1" SVM. The customer wants to enable nondisruptive operations (NDO) to prevent future failures.
In this scenario, which two actions must be performed? (Choose two.)
- A. Verify that SMB2 is enabled.
- B. Verify that the continuously-available option is set on the CIFS share.
- C. Verify that the branchcache option is set on the CIFS share.
- D. Verify that SMB3 is enabled.
Answer: A,B
NEW QUESTION 16
You configured iSCSI multipathing on a Windows host to a 2-node ONTAP cluster so that you can attach to some LUNs. You see that the host logging in to both iSCSI LIFs in the ONTAP cluster, and you notice that the igroup is correctly set. After you open Disk Management and rescan for disks, the NetApp LUNs do not show up.
In this scenario, what should be performed to enable the LUNs to be visible to the Windows host?
- A. Set up Selective LUN Mapping (SLM) and try scanning again.
- B. Configure the ONTAP nodes for HA and try scanning again.
- C. Set up LUN mapping and try scanning again.
- D. Configure the SVM for FCP and try scanning again.
Answer: A
NEW QUESTION 17
After you replaced the motherboard, the node stopped in the "waiting for the cluster application to come online" state.
Which two actions should you perform to troubleshoot this problem? (Choose two.)
- A. Verify that the physical links on the cluster ports are up.
- B. Check the status of the HA with the interconnect-up field of storage failover show command.
- C. Check the status of the cluster with the cluster ring show command.
- D. Verify the setting of the cluster interconnect switch.
Answer: B,C
NEW QUESTION 18
A customer mentions that their intercluster SnapMirror replication operations consistently take much longer than normal. While troubleshooting, you want to initiate a test SnapMirror session to collect performance data.
How would you accomplish this task?
- A. Run the network test-path command to simulate a SnapMirror connection and record the latency/throughput data.
- B. View the active network connections to the node to see if there a large number of active connections.
- C. Use the ifstat command to collect network performance data for the physical interface.
- D. Run the network statistics lif show command for the intercluster LIF to simulate a network connection.
Answer: A
NEW QUESTION 19
Click the exhibit button.
Your customer reports that their FAS2554A system reports multi-path HA when running the sysconfig command. However, Config Advisor reports an error about incorrect cabling.
What are the two reasons for the messages? (Choose two.)
- A. The FAS2554 system is cabled incorrectly to shelf ID 20.
- B. Shelves 10 and 20 have different IOM modules and must be in separate stacks.
- C. The DS2246 shelf is wrong; the shelf ID must be 11.
- D. Disk shelves 10 and 20 are cabled incorrectly to each other.
Answer: A,D
NEW QUESTION 20
Click the exhibit button.
A volume move operation has been initiated to move a volume named MirrScr from one aggregate to another.
The operation failed with the error that is shown in the exhibit.
In this scenario, which statement is correct?
- A. There are too many snapshots on the source volume.
- B. The volume move cannot be completed at this time because of high use in this node.
- C. Manually trigger the cutover process in order to restart the job.
- D. Cancel and restart the volume move operation.
Answer: C
NEW QUESTION 21
The root aggregate on your single-node ONTAP cluster failed. You have the configuration backups saved on your FTP server?
In this scenario, which two steps are part of the recovery procedure? (Choose two.)
- A. Create a new root aggregate and set its ha_policy option to cfo.
- B. Perform a Netboot using the configuration backup.
- C. Create a new aggregate and set its ha_policy option to sfo.
- D. Boot into maintenance mode.
Answer: A,D
NEW QUESTION 22
Click the exhibit button.
A customer's system reported several errors. There was no disruption, but the customer is concerned about the system's health.
Referring to the exhibit, which statement is true?
- A. One of the IOM modules on shelf 20 has failed.
- B. Port 1D on the system has failed.
- C. Storage redundancy is degraded.
- D. One of the switches has failed.
Answer: C
NEW QUESTION 23
You are running a fabric-attached MetroCluster configuration with ONTAP 9.5software. There is a maintenance window for the upcoming weekend. Plexes in your mirrored aggregates between your two data centers have not been synchronizing for two days.
When the resynchronizations begin, they are not as quick as expected, and the process takes more than a day.
You have been modifying the number of concurrent I/O streams using the storage raid-options modify raid.
resync.num_concurrent_ios_per_rg command, but the resynchronization speed stays slow.
You have four separate ISLs between your data centers using Brocade 6510 switches. Hardware problems are not an issue.
Which two actions should you take to prevent this problem in the future?
(Choose two.)
- A. Avoid changes on your aggregates during the maintenance window.
- B. Update to at least ONTAP 9.4 software.
- C. Take the corresponding plexes offline before maintenance to avoid a base-level synchronization.
- D. Restart the resynchronizations after modifying storage raid-options modify raid.resync.num_concurrent_ios_per_rg command.
Answer: B,D
NEW QUESTION 24
A customer reports that copying data over iSCSI attached LUNs is taking significantly longer than usual. The customer asks you to help to identify the root cause of this problem.
Which two perfstat sections would you use to accomplish this task? (Choose two.)
- A. stats lun
- B. stats volume
- C. statit
- D. lun stats -vserver
Answer: C,D
NEW QUESTION 25
A field support engineer has just replaced the IOXM on NODE2 on a FAS8080 running ONTAP 9.1. After the replacement, the customer is unable to perform a giveback because the interconnect is down.
In this scenario, which statement is correct?
- A. Verify that the interconnect cables on the IOXM are connected correctly.
- B. Verify that there cross-links between the interconnects.
- C. Verify that the interconnect cables on the motherboard are connected correctly.
- D. Verify that the installed FC-VI cards are configured properly.
Answer: A
NEW QUESTION 26
Click the exhibit button.
Referring to the exhibit, which change is required to enable the CIFS Autolocation function for the Users share?
- A. Re-create the LIFs to allow both CIFS and NFS protocols.
- B. Edit the CIFS share's properties to remove the changenotify property.
- C. Modify the CIFS server's option to enable SMB multichannel.
- D. Change the CIFS share's Symlink Properties parameter to symlinks.
Answer: D
NEW QUESTION 27
You have a 2-node ONTAP Select HA deployment. In this scenario, which application manages the quorum, if one node fails?
- A. Tiebreaker
- B. ONTAP Mediator
- C. vCenter Server
- D. ONTAP Deploy VM
Answer: D
NEW QUESTION 28
In a 4-node cluster, nodes 1 and 2 are an HA pair, and nodes 3 and 4 are an HA pair. The following error appears in the log.
12/15/2018 15:48:47 node-2CRITICALclam.node.ooq: Node (name=node- 2, ID= 1001) is out of "CLAM quorum" (reason =quorum update).
In this scenario, which two statements are correct? (Choose two.)
- A. Node 2 takes over node 1.
- B. All LUNs are online in the cluster.
- C. Node 1 takes over node 2.
- D. All LUNs are offline in the cluster.
Answer: C,D
NEW QUESTION 29
Click the exhibit button.
A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.
Referring to the exhibit, which statement is correct?
- A. The problem is due to a difference in operation size.
- B. Perfstat should be used to explain the behavior.
- C. A case with NetApp should be raised to find the root cause.
- D. There are operation types that are not listed in the output.
Answer: A
NEW QUESTION 30
The error message shown below is reported in the EMS log file.
"[sis.changelog.full:warning]: Change logging metafile on volume DATA1 is full and can not hold any more fingerprint entries." What are two ways to solve this problem? (Choose two.)
- A. Increase the size of the changelog to allow the operation to continue.
- B. Modify the threshold that triggers a deduplication operation.
- C. Clear the changelog manually so that the operation can restart.
- D. Modify the storage efficiency policy so that deduplication runs more frequently.
Answer: A,B
NEW QUESTION 31
Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.
In this scenario, what is the reason for the behavior?
- A. The volume move command uses the intercluster LIFs, not the data LIFs.
- B. The volume move command uses the HA iWarp interconnect, not the client access switches.
- C. The volume move command uses copy offload protocol, so it does not show up when monitored.
- D. The volume move command uses the cluster interconnect switches, not the client access switches.
Answer: C
NEW QUESTION 32
A customer reports that one their SVMs has two default gateways. The customer wants to know whether this behavior is expected or if one of gateways should be deleted.
In this scenario, what do you tell the customer?
- A. This situation is a misconfiguration, and the customer should delete one of the default gateways because there can be only gateway for each SVM.
- B. The configuration is acceptable only if both default gateways are in the same subnet.
- C. The configuration is acceptable if the customer configures different metrics on all defaults routes.
- D. The configuration is acceptable. The customer can achieve load balancing between the default gateways by setting the same metric on all default routes.
Answer: C
NEW QUESTION 33
Click the exhibit button.
A customer notifies you that Active IQ is showing a warning that a broadcast domain in their environment has been configured with ports from multiple VLANs.
Referring to the exhibit, which two statements are correct? (Choose two.)
- A. You should move the e0M ports to a Broadcast Domain that is dedicated to only management traffic.
- B. A VLAN tag cannot be assigned to the e0M port, so the configuration is acceptable.
- C. You should change the LIF service policy to net-intercluster to prevent the LIFs from failing over to the e0M ports.
- D. You should configure e0M so that is tagged on VLAN 40.
Answer: C,D
NEW QUESTION 34
A new cluster running ONTAP 9.5 has just been installed and you want to create a FlexGroup volume. Which action will accomplish this task?
- A. Use the storage pool create command.
- B. Use the volume size command.
- C. Use the volume create command.
- D. Use the Deploy utility to provision the FlexGroup volume.
Answer: A
NEW QUESTION 35
For restore purposes, a storage administrator on an ONTAP system created a FlexClone of a volume that contains a LUN from a specific snapshot. This LUN cannot be seen by a Windows client after a disk rescan is performed by using Disk Management.
In this scenario, which statement is correct?
- A. The cloned LUN needs to be mapped to an initiator group.
- B. The cloned LUN must be brought online.
- C. The cloned LUN must be renamed to a different name than the name of the source LUN.
- D. The cloned volume must be split from the source volume before the LAN can be used.
Answer: D
NEW QUESTION 36
A customer's FAS8200 node1 went down an hour ago after a WAFL inconsistency error. All data is being served from partner node2, but the storage failover show command output is not showing a node1 as "Waiting for giveback".
What is the corrective action for this situation?
- A. Re-create the root aggregate on node1.
- B. Boot the system and run the wafliron command on the inconsistent data aggregate.
- C. Boot the system and run the WAFL_check command on the inconsistent data aggregate.
- D. From the LOADER prompt, run the wafliron command on the system's root aggregate.
Answer: A
NEW QUESTION 37
A customer reports that a takeover has been disabled on an HA pair.
What would be a cause for this to happen?
- A. The cluster network is not functioning properly.
- B. The interface for the hardware assist has become unavailable.
- C. There is a disk running too hot.
- D. The HA interconnect is not functioning properly.
Answer: D
NEW QUESTION 38
Which two statements are true about a data volume? (Choose two.)
- A. A data volume can be accessed by a user connected to any SVM.
- B. A data volume can be accessed by a LIF on any node.
- C. An SVM root or root load sharing mirror volume must be present on every node.
- D. A data volume can be moved to any aggregate with space for it in the cluster.
Answer: B,D
NEW QUESTION 39
......
Free Network Appliance NCSE NS0-592 Exam Question: https://testinsides.actualpdf.com/NS0-592-real-questions.html
